• Zero Sequence Current Transformer Detects Current Appliances for Fire and Leakage Protection
  • Zero Sequence Current Transformer Detects Current Appliances for Fire and Leakage Protection
  • Zero Sequence Current Transformer Detects Current Appliances for Fire and Leakage Protection
  • Zero Sequence Current Transformer Detects Current Appliances for Fire and Leakage Protection
  • Zero Sequence Current Transformer Detects Current Appliances for Fire and Leakage Protection
  • Zero Sequence Current Transformer Detects Current Appliances for Fire and Leakage Protection

Zero Sequence Current Transformer Detects Current Appliances for Fire and Leakage Protection

Application: Electronic, Instrument, Position Sensor
Type: Current Transformer
Phase: Single
Operation Condition: Outdoor
Usage: Protection, Measurement
Winding Form: Multilayer Flat Winding
Samples:
US$ 5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Jiangsu, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
to see all verified strength labels (27)

Basic Info.

Model NO.
DL-LXQ26AL
Insulating Medium
Epoxy Resin
Installation
Bus Perforation and Secondary Lead Output
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Electromagnetic Type
Magnetic Core
High Permeability Amorphous Nanoc
Flame Retardant Property
UL94-Vo
Operating Temperature
40ºC~+85ºC
Normal Ratio
1000megohm
Transport Package
Carton
Specification
0.00000765cubic meter
Trademark
njxse
Origin
Nanjing, Jiangsu, China
HS Code
8504311000
Production Capacity
Four Million Pieces/Year

Product Description

DL-LXQ26ALurrent transformer is an efficient product independently developed and designed by our company. The product has a flame retardant performance of UL94-VO, a normal insulation resistance ratio of 1000MΩ, a working voltage of 0.66/0.72kv and a compressive strength of 2kv/50Hz/ min. The operating frequency of the product is 50~200KHz, and the operating temperature is 40ºC - +85ºC. The product is used in load current detection, power measurement and microcomputer protection. Our products are available in two mounting modes: bus perforation and secondary lead output. Please see the picture below for the specific parameters and three views of the product.
Our company's products use high quality raw materials, in line with the safety standards of various countries.More than 10 years of research and development team, ingenuity of seiko production.
Automated production equipment, man-machine integration of testing and verification system.
Leading peer quality products are the only choice to help your business take off.
Brand advantage:ISO 9001:2015 system certification, product CE certification.

Customer advantage:Brought together a group of experienced industrial product appearance designers, material engineers, structural engineers, electrical engineers, can provide customers with new product customization development.
For industry customers, the first to build a cloud platform information release system, client information system, e-commerce ordering system.
Overall technical assistance from product improvement to mold manufacturing, product shell production and processing, post-processing surface post-treatment.
Service advantage:Five-star business team, to give you satisfactory service.
Senior engineering research and development team, to provide you with technical support, tailored to design all kinds of transformers.
Professional purchasing staff, to provide you with value for money raw materials.
Creative production team, to provide you with high quality transformer products.
Critical quality personnel, for you to solve the product worries.
Note: that the current transformer cannot be used in open circuit or connected to a fuse. Connect the output of the transformer first, and then clamp the transformer to the bus under test.

Parametric diagram:
Zero Sequence Current Transformer Detects Current Appliances for Fire and Leakage Protection

Following are our product details and factory production displays:Zero Sequence Current Transformer Detects Current Appliances for Fire and Leakage Protection
Zero Sequence Current Transformer Detects Current Appliances for Fire and Leakage Protection
Welcome to visit our factory:
Zero Sequence Current Transformer Detects Current Appliances for Fire and Leakage ProtectionZero Sequence Current Transformer Detects Current Appliances for Fire and Leakage ProtectionZero Sequence Current Transformer Detects Current Appliances for Fire and Leakage Protection

Quality determines safety, choose unsafe low-cost products if there is an accident, everything is empty talk

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2024

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
5000000 RMB
Plant Area
>2000 square meters